NEW QUESTION 171
Which of the characteristics of UPS5000-A regarding intelligence are correct? (Multiple choice)
- A. The NetEco monitoring software of UPS5000-A supports SMS or E-mail remote alarm
- B. Support NetEco monitoring software, support centralized monitoring of UPS
- C. Support battery intelligent management, effectively prolong battery life
Answer: A,B,C
NEW QUESTION 172
FusionModule solution can use ECC800 to achieve local monitoring, and use NetEco management system to achieve centralized monitoring of multiple micro-modules.
Then, in the project bidding quotation, which product is the configuration quotation of the ECC800 collector in?
- A. FusionModule Solution
- B. None of the above is true
- C. UPS products
- D. NetEco Management System
Answer: D
NEW QUESTION 173
When installing NETECL5000-A35KW, generally at least pre-charge () KG refrigerant.
- A. 0
- B. 1
- C. 2
- D. 3
Answer: B
NEW QUESTION 174
The parameter display of the PDU8000 smart power meter is abnormal, which may be due to? (Multiple choice)
- A. Corresponding current transformer fault
- B. The current or voltage change is set incorrectly
- C. The corresponding voltage acquisition circuit is abnormal
- D. Smart power meter failure
Answer: A,B,C,D
NEW QUESTION 175
NETCOL5000-C temperature and humidity sensor dial-code setting error may cause:
- A. The drainage capacity of the equipment is significantly reduced
- B. The temperature and humidity sensor cannot detect the temperature and humidity
- C. Water leakage at the bottom of the device
- D. The return air temperature or fan speed fluctuates greatly
Answer: B
NEW QUESTION 176
Three groups of 9AH battery packs are connected in parallel to UPS2000-G-6KVA, the battery capacity should be set to ().
- A. 9AH
- B. 32AH
- C. 27AH
- D. 18AH
Answer: C
NEW QUESTION 177
The dry contact signal of UPS5000-E does not support the remote emergency stop function.
- A. FALSE
- B. TRUE
Answer: A
NEW QUESTION 178
The maximum effective distance of WIFI supported by NETECO's mobile APP is () meters.
- A. 0
- B. 1
- C. 2
- D. 3
Answer: C
NEW QUESTION 179
The type of UPS5000-E is ( )
- A. High frequency tower
- B. High Frequency Modularity
- C. Power frequency machine
Answer: A
NEW QUESTION 180
The NetEco6000 management system supports virtualized deployment and adapts to the rhythm of future cloudification.
- A. False
- B. True
Answer: B
NEW QUESTION 181
The signal processing of the UPS5000-E will centralize control:
- A. Maintenance Bypass Module
- B. Bypass Module
- C. Power Module
- D. Energy Control Module ECM
Answer: D
NEW QUESTION 182
What are the alarm management functions supported by the ECC800? (Multiple choice)
- A. Alarm parameter setting
- B. Alarm data export
- C. Filter alerts
- D. View historical alarms
Answer: A,B,C,D
NEW QUESTION 183
The damage of NETCOL5000-C thermal insulation cotton may cause:
- A. The drainage capacity of the equipment is significantly reduced
- B. The fan noise is too loud
- C. Pipeline condensation
- D. The fan is blocked
Answer: C
NEW QUESTION 184
UPS5000-A has built-in SNMP and ModBus card to reduce the management investment cost of customers.
- A. False
- B. True
Answer: B
NEW QUESTION 185
The smart ETH socket supports up to () cascades.
- A. 0
- B. 1
- C. 2
- D. 3
Answer: B
NEW QUESTION 186
When a fire breaks out in the box and the fire extinguishing device releases the fire extinguishing agent into the protection area, ( ) will display the words "In The Vent, Do Not Enter".
- A. Sound and light alarm
- B. Fire alarm
- C. Deflation indicator light
- D. Emergency Lights
Answer: C
NEW QUESTION 187
The UPS5000-E power chess block adopts a fan fault-tolerant design. When two of the fans are damaged, what percentage of the power module can still be loaded?
- A. 0.6
- B. 0.3
- C. 0.5
- D. 0.2
Answer: C
NEW QUESTION 188
In a project that requires the deployment of three-layer temperature cloud maps in a high-density area, ( ) temperature probes need to be deployed in each cabinet. (Fill in the blank)
- A. 3
Answer: A
NEW QUESTION 189
Which of the following functions does PDU8000 precision power distribution cabinet mainly have? (Multiple choice)
- A. The precision power distribution cabinet supports SNMP and MODBUS communication, which can transmit information to the intelligent monitoring system.
- B. Abnormal alarm function of main circuit and sub-circuit of precision power distribution cabinet
- C. Protection function of the lower line and equipment of the precision power distribution cabinet
- D. Main circuit and sub-circuit metering function of precision power distribution cabinet
- E. Power distribution function of data center micro-module (cabinet)
Answer: A,B,C,D,E
NEW QUESTION 190
What are the functions provided by the Huawei surveillance system NETECO? (Multiple choice)
- A. Support modular/cabinet-level view display
- B. Only provide view creation tools to facilitate and quickly configure views
- C. Provide 2D, 3D data center view display
- D. Support system power distribution view display
Answer: A,B,C,D
NEW QUESTION 191
UPS5000-E can accept the input voltage within the range of ( ) V.
- A. 138-485
- B. 305-485
- C. 120-480
- D. 140-490
Answer: A
NEW QUESTION 192
......